FMTD SERIES SPECIFICATIONS

All materials in contact with the fluid media are 316 stainless steel and PTFE.
         

LR76077
Explosion Proof, Class I, Division 1, Groups C & D Certified By Canadian Standards Association.
INTRINSICALLY SAFE Certification by CSA (Added Cost Option "IS").

         
Ranges:
FMTD4: <.015-4.00 GPH [1-250 ccpm]
FMTD20: <.075 -20.00 GPH [5 - 1250 ccpm]
  Displacement:
FMTD4: Approximately 50 pulses per cc
FMTD20: Approximately 10 pulses per cc
         
Accuracy:
+/- 0.5%
  Temp. Range:
-40 To +180 F [-40 To +80]
         
Repeatability:
+/- 0.1%
  Power:
8 - 30 VDC, 50 milliamps maximum
         
Output Signal:
0 - 5 Volt Square Wave
  Power/Signal Cable:
3 Feet [1 Meter] Long
         

Maximum Operating Pressure:
3,000 psig [21 MPa] Standard
21,000psi [147 MPa] Added Cost Option "P"

  Process Connections:
1/4"NPT
         
Max. P: 5 psi [34kPa] FMTD4
15 psi [102kPa] FMTD20
  Conduit Connection:
1/2" NPT
         
Dimensions: 2.50" D. X
4.63 " L. [6.4 cm D. X 11.8 cm L.]
  Weight:
2.9 Pounds [1.32 Kg.]
         
Viscosity: 100 SSU [25 cp] Maximum Recommended. Higher Viscosities Reduce Low Flow Rate Capabilities.